Intrinsically Safe Differential Pressure Transmitter
Intrinsically safe Differential Pressure Transmitter for Hazardous Zone Pressure and Flow Applications. It provides 4-20mA process output. a robust NEMA 4X enclosure, a large LCD display that can be programmed to read in pressure, velocity or flow. It provides 0.5% full accuracy on ranges from 0.25 inch wc to 100 inch wc as well as bidirectional models upto 10 inch wc. It is an ideal instrument for monitoring pressure or air flows in hazardous zones having a Class I Div. I Groups A, B, C, D; Class II Div.I Groups E, F, G, Class Div.I ratings
1529416104
Intrinsically Safe Differential Pressure Transmitter Intrinsically safe Differential Pressure Transmitter for Hazardous Zone Pressure and Flow Applications. It provides 4-20mA process output. a robust NEMA 4X enclosure, a large LCD display that can be programmed to read in pressure, velocity or flow. It provides 0.5% full accuracy on ranges from 0.25 inch wc to 100 inch wc as well as bidirectional models upto 10 inch wc. It is an ideal instrument for monitoring pressure or air flows in hazardous zones having a Class I Div. I Groups A, B, C, D; Class II Div.I Groups E, F, G, Class Div.I ratings
Aerosense Differential Pressure cum Flow Transmitter is technically engineered type of flow transmitter that is especially used in HVAC/R industry to control the flow, velocity and static of air pressure. Apart from measuring the flow of air control, this type of transmitter is used in the other major applications such as VAV domain and air flow monitoring across centrifugal fans & blowers. It supports low power consumption as well as enabled with the zero point calibration system.
1528645139
Aerosense Differential Pressure cum Flow Transmitter is technically engineered type of flow transmitter that is especially used in HVAC/R industry to control the flow, velocity and static of air pressure. Apart from measuring the flow of air control, this type of transmitter is used in the other major applications such as VAV domain and air flow monitoring across centrifugal fans & blowers. It supports low power consumption as well as enabled with the zero point calibration system.
Wet Differential Pressure Transmitter
Dwyer Wet/Wet Differential Pressure Transmitter with 0.5% accuracy and NEMA 4X (IP66) enclosure. It monitors differential pressure of air and compatible gases and liquids. Output signal of 4-20mA or optional 0-10VDC, 0-5VDC. Features: Span and zero controls reduce installation and service time. Terminal block reduces wiring difficulties saving installation time. Optional LED indicator provides local status to identify operational conditions. Optional 3-way valve manifold supports high line pressure. Applications: Flow elements Heat Exchangers Filters Coils Chiller Pumps
1528128564
Wet Differential Pressure Transmitter Dwyer Wet/Wet Differential Pressure Transmitter with 0.5% accuracy and NEMA 4X (IP66) enclosure. It monitors differential pressure of air and compatible gases and liquids. Output signal of 4-20mA or optional 0-10VDC, 0-5VDC. Features: Span and zero controls reduce installation and service time. Terminal block reduces wiring difficulties saving installation time. Optional LED indicator provides local status to identify operational conditions. Optional 3-way valve manifold supports high line pressure. Applications: Flow elements Heat Exchangers Filters Coils Chiller Pumps
Magnehelic Gauge
Select the Magnehelic® gage for high accuracy--guaranteed within 2% of full scale--and for the wide choice of 81 models available to suit your needs precisely. Using Dwyer's simple, frictionless Magnehelic® gage movement, it quickly indicates low air or non-corrosive gas pressures--either positive, negative (vacuum) or differential. The design resists shock, vibration and over-pressures. No manometer fluid to evaporate, freeze or cause toxic or leveling problems. It's inexpensive, too. The Magnehelic® gage is the industry standard to measure fan and blower pressures, filter resistance, air velocity, furnace draft, pressure drop across orifice plates, liquid levels with bubbler systems and pressures in fluid amplifier or fluidic systems. It also checks gas-air ratio controls and automatic valves, and monitors blood and respiratory pressures in medical care equipment. Note: May be used with Hydrogen. Order a Buna-N diaphragm. Pressures must be less than 35 psi. Product Applications: Filter Monitoring Air Velocity with Dwyer Pitot Tube Blower Vacuum Monitoring Fan Pressure Indication Duct, Room or Building Pressures Clean Room Positive Pressure Indication
1527590957
Magnehelic Gauge Select the Magnehelic® gage for high accuracy--guaranteed within 2% of full scale--and for the wide choice of 81 models available to suit your needs precisely. Using Dwyer's simple, frictionless Magnehelic® gage movement, it quickly indicates low air or non-corrosive gas pressures--either positive, negative (vacuum) or differential. The design resists shock, vibration and over-pressures. No manometer fluid to evaporate, freeze or cause toxic or leveling problems. It's inexpensive, too. The Magnehelic® gage is the industry standard to measure fan and blower pressures, filter resistance, air velocity, furnace draft, pressure drop across orifice plates, liquid levels with bubbler systems and pressures in fluid amplifier or fluidic systems. It also checks gas-air ratio controls and automatic valves, and monitors blood and respiratory pressures in medical care equipment. Note: May be used with Hydrogen. Order a Buna-N diaphragm. Pressures must be less than 35 psi. Product Applications: Filter Monitoring Air Velocity with Dwyer Pitot Tube Blower Vacuum Monitoring Fan Pressure Indication Duct, Room or Building Pressures Clean Room Positive Pressure Indication
Single Pressure Manometer
Dwyer Single Pressure Digital Manometer can be used to used to measure low pressure with +/- 1.5% FS accuracy. Features: Rugged extruded aluminium housing. One button auto-zero function. Auto power off function to conserve battery life. Instant selection of upto 9 English/metric units. Applications: Verify field instrumentation performance. Adjust fuel mixture on combustion systems.
1527087781
Single Pressure Manometer Dwyer Single Pressure Digital Manometer can be used to used to measure low pressure with +/- 1.5% FS accuracy. Features: Rugged extruded aluminium housing. One button auto-zero function. Auto power off function to conserve battery life. Instant selection of upto 9 English/metric units. Applications: Verify field instrumentation performance. Adjust fuel mixture on combustion systems.