MAHNDIHASAN9BD8 597b1af0addb68057c0d61c5 False 93 107
OK
Updates

No results found!

Duct and Immersion Building Automation Temperature Sensor: The Series TE Duct and Immersion Temperature Sensor can be used to monitor air or water temperature throughout a building management system or an air handler unit. Flanged duct sensors monitor the supply or return air and provide a thermistor or RTD output to the digital controller. Immersion sensors which are supplied with compression fittings are typically used to monitor the hot or chilled water lines throughout a building. Thermowells are recommended, but not required on the immersion sensors. For variable air volume applications, the Series TE can be configured to have plenum rated cable with flying leads. Standard units come with leads with an integral terminal block to eliminate carrying extra wire nuts. For housing models, multiple knockouts provide easy conduit access to any side of the housing. The 1/4 turn lid comes with a chain to prevent it from being lost during installation.
1513259875
Duct and Immersion Building Automation Temperature Sensor: The Series TE Duct and Immersion Temperature Sensor can be used to monitor air or water temperature throughout a building management system or an air handler unit. Flanged duct sensors monitor the supply or return air and provide a thermistor or RTD output to the digital controller. Immersion sensors which are supplied with compression fittings are typically used to monitor the hot or chilled water lines throughout a building. Thermowells are recommended, but not required on the immersion sensors. For variable air volume applications, the Series TE can be configured to have plenum rated cable with flying leads. Standard units come with leads with an integral terminal block to eliminate carrying extra wire nuts. For housing models, multiple knockouts provide easy conduit access to any side of the housing. The 1/4 turn lid comes with a chain to prevent it from being lost during installation.
Averaging Flow Sensor: Product Details: Brand Dwyer Length 12-1/2
1510567380
Averaging Flow Sensor: Product Details: Brand Dwyer Length 12-1/2" to 23-29/32" (31.75 to 60.72 cm) Sensing points Up to 10 Models PAFS-1006 to PAFS -1011 Accommodate box diameter 4" to 16" (10.16 to 40.64 cm) The Series PAFS-1000 Averaging Flow Sensor is ideal for sensing differential pressure in the inlet section of variable air volume terminal units and fan terminal units. Units can also be used to sense differential pressure at other locations in the main or branch duct systems. The "H" port senses total pressure and the "L" port senses static pressure. The difference between these signals is the differential or velocity pressure. Product Applications Zone control in HVAC systems
Carbon Dioxide Sensor: Product Details: Measurement range 0-2000 ppm Duct Air Velocity 0 to 1500 ft/min Accuracy +/- 40ppm +3% of reading Output voltage 0-10 VDC Air ducts range Less than 6 in HVAC Telaire Duct Mount CO2 Transmitter can be used in broad range of applications including air quality monitoring in buildings. Features of Carbon Dioxide Sensor: CO2 concentration levels in buildings are monitored to provide an indication of occupancy An effective Demand Controlled Ventilation strategy will conserve energy and maintain indoor air quality One of the smallest in duct CO2 transmitters in market Simple installation Ideally suited for OEM manufacturers that must accomadate smaller HVAC return air ducts Patented absorption infrared/gas sensing engine provides high accuracy in a compact low cost Patented ABC Logic self calibration system eliminates the need for manual calibration in most applications Lifetime calibration guarantee
1511668710
Carbon Dioxide Sensor: Product Details: Measurement range 0-2000 ppm Duct Air Velocity 0 to 1500 ft/min Accuracy +/- 40ppm +3% of reading Output voltage 0-10 VDC Air ducts range Less than 6 in HVAC Telaire Duct Mount CO2 Transmitter can be used in broad range of applications including air quality monitoring in buildings. Features of Carbon Dioxide Sensor: CO2 concentration levels in buildings are monitored to provide an indication of occupancy An effective Demand Controlled Ventilation strategy will conserve energy and maintain indoor air quality One of the smallest in duct CO2 transmitters in market Simple installation Ideally suited for OEM manufacturers that must accomadate smaller HVAC return air ducts Patented absorption infrared/gas sensing engine provides high accuracy in a compact low cost Patented ABC Logic self calibration system eliminates the need for manual calibration in most applications Lifetime calibration guarantee
Aerosense Air Flow Transmitter: Aerosense Differential Pressure cum Flow Transmitter engineered for building automation in HVAC/R industry. It measures volume flow, velocity and static and differential pressure. The DPT-Flow devices can be connected directly to pressure measurements points in the centrifugal fan. Features of Aerosense Air Flow Transmitter : ZERO point calibration i.e. Automatic autozero or manual pushbutton Selectable Flow units Optional Auto-Zero feature (AZ)- The AZ calibration electronically adjusts the transmitter zero at predetermined time intervals (every 10 minutes). The AZ calibration eliminates all output signal drift due to thermal, electronic or mechanical effects Applications of Aerosense Air Flow Transmitter: Airflow monitoring across centrifugal fans and blowers In-duct airflow monitoring VAV applications
1513830311
Aerosense Air Flow Transmitter: Aerosense Differential Pressure cum Flow Transmitter engineered for building automation in HVAC/R industry. It measures volume flow, velocity and static and differential pressure. The DPT-Flow devices can be connected directly to pressure measurements points in the centrifugal fan. Features of Aerosense Air Flow Transmitter : ZERO point calibration i.e. Automatic autozero or manual pushbutton Selectable Flow units Optional Auto-Zero feature (AZ)- The AZ calibration electronically adjusts the transmitter zero at predetermined time intervals (every 10 minutes). The AZ calibration eliminates all output signal drift due to thermal, electronic or mechanical effects Applications of Aerosense Air Flow Transmitter: Airflow monitoring across centrifugal fans and blowers In-duct airflow monitoring VAV applications
By keeping in mind the track of advanced market development, we are engaged in offering an exclusive range of Dwyer Air Velocity Transmitter. It is an ideal instrument for measuring the flow of clean air & non-combustible gases. Extremely demanded in processing industries, this Dwyer Air Velocity Transmitter is made available in numerous specifications that are designed using latest technology. The offered Dwyer Air Velocity Transmitter is broadly acknowledged among our clients for its optimum quality, fine finish and durability. Apart from this, our clients can avail this transmitter from us at market leading prices.

Features of Dwyer Air Velocity Transmitter:
Rugged design
Smooth performance
Highly efficient
1514205883
By keeping in mind the track of advanced market development, we are engaged in offering an exclusive range of Dwyer Air Velocity Transmitter. It is an ideal instrument for measuring the flow of clean air & non-combustible gases. Extremely demanded in processing industries, this Dwyer Air Velocity Transmitter is made available in numerous specifications that are designed using latest technology. The offered Dwyer Air Velocity Transmitter is broadly acknowledged among our clients for its optimum quality, fine finish and durability. Apart from this, our clients can avail this transmitter from us at market leading prices. Features of Dwyer Air Velocity Transmitter: Rugged design Smooth performance Highly efficient

Our timings

[IS_BIZ_OPEN] Mon: 9:00AM  -  6:00PM
[IS_BIZ_OPEN] Tue: 9:00AM  -  6:00PM
[IS_BIZ_OPEN] Wed: 9:00AM  -  6:00PM
[IS_BIZ_OPEN] Thu: 9:00AM  -  6:00PM
[IS_BIZ_OPEN] Fri: 9:00AM  -  6:00PM
[IS_BIZ_OPEN] Sat: 9:00AM  -  6:00PM
[IS_BIZ_OPEN] Sun: Closed  -  Closed

Contact

Chennai, Tamil Nadu
+91 8079486684  or   or   
Please keep or 0 before the
number when you dial.
Share Tweet
13.0826802 80.2707184000001 A L M Engineering & Instrumentation Pvt. Ltd Chennai, Tamil Nadu